SCROLL DOWN THE PAGE FOR
MORE HELP PICTURES
Load Master Tipped or Missing Small Primers
Load Master Primer Ledge in Carrier to be Cleaned
The arrow points to the ledge that needs to be clear of any debris to allow the primer pin to drop down all the way.
Auto Disk Over-Travel Fix
Auto Disk Powder Leakage Fix
Remove Hopper and Disk to file or sand the tops of the 2 risers.
Put a layer of scotch tape on top of the disk and carefully file or sand the risers.
Properly Installed Adjustable Charge Bar
Titan Micro Charge Installation
1. The “Drop Bar” goes on first with the raised round portion around the hole inserted down into the drop hole of the powder measure.
2. The “Micro Disk” fits over the “Drop Bar” with the actuating lever of the powder measure engaged into the slot on the bottom of the disk in the same way that the standard disks do.